Ignis Doors

Installing Fire Doors: Ignis UK Tutorial

Date: 18/10/2023

Posted by: ignis

Fire doors are essential in protecting lives and property during a fire. Their design and installation are strictly regulated, and for a good reason: they are a key line of defense in slowing the progression of a fire. That gives people a chance to escape a burning house safely.

The Importance of Fire Doors

Gaining insight into the essential role fire doors play in building safety is necessary before delving into the specifics of installing fire door frames. Finding an exit in the case of a fire is difficult due to the chaos that occurs. Fire doors are the protectors, serving as vital barriers that keep people safe from dangerous fire threats.

Fire doors are built to resist a fire’s high temperatures and pressures. They’re made of fire-resistant materials and frequently include intumescent seals that expand when exposed to heat. This valuable time might make the difference between life and death.

Choosing the Best Frame for Your Fire Door

Every fire door component must meet stringent fire safety regulations. The key is to get a fire door frame made by a qualified manufacturer that satisfies the strict fire resistance criteria. The kind of fire door you wish to install should be considered while selecting a fire door frame.

Let’s look more closely at these variations:

1. FD30-Rated Fire Door

This is the standard option for many residential buildings. A fire door rated FD30 can successfully stop the spread of a fire for roughly 30 minutes. You’ll need an FD30-rated fire door liner to go with this door. The good news is that these 30-minute frames are built from various wood and wood-based materials as long as they meet the parameters given in the data sheets. This material flexibility provides you with alternatives while also ensuring that you fulfill safety regulations.

2. FD60-Rated Fire Door

The FD60-rated fire door provides greater fire resistance for specified applications. It can keep a fire at bay for up to 60 minutes. To match this increased level of fire protection, the fire door frame must be made of steel.

3. FD120-Rated Fire Door

The FD120-rated fire door is the best option for maximum fire protection. It can endure an attack of fire for an astounding 120 minutes. These doors are commonly encountered in industrial environments where safety is paramount.

Your choice of fire door frame is critical to your safety and property protection. Each frame type serves a different function and has performance characteristics, so making an informed choice is vital.

Ensuring a Secure Fire Door Installation

As we progress through fire door installation, attention to detail becomes increasingly important. Let’s look at the important checklist for installing your fire door.

Before Installation

Several elements must be kept in mind while installing a fire door.

  • Check if the fire door is certified. Look for a label or a plug on the door and the frame. This information validates the door’s fire rating and gives you significant insight into its functioning as a fire door.
  • Ensure that the fire door is accompanied by adequate documentation. This paperwork should include fitting instructions that will serve as your guide to proper installation. Following these instructions precisely is critical to the door’s operation.
  • Cross-reference the frame specification with the fire rating of the door. Ideally, it’s vital to ensure the door and framework are together to contain a fire.
  • Check the ironmongery provided for the door once more. It should be compatible with the design and function of the door.
  • The installation of intumescent seals must be done correctly.

When exposed to heat, these seals expand, producing a barrier against the infiltration of smoke and fire. In the event of a fire, they are a lifeline.

Post-Installation Checklist

Even after installation, your path to fire door safety continues. Necessary post-installation tests must be performed to ensure your fire door is ready to save lives. As the door closes, pay close attention. It should make a robust and comforting sound when it hits the frame. When closed, the gaps around the door must be constant and no larger than 3-4mm.

  • Scrutinize the surface of the door. Is there any evidence of wear and tear?
  • Check the door for splits, cracks, or missing pieces. These might jeopardize the door’s fire resistance.
  • From every aspect, the door should securely close upon the latch. Test it by opening the door only a few inches, halfway, then altogether. It should always latch securely.
  • Is the light coming in through the space at the bottom of the door? If this is the case, check the documentation for the door to confirm that the maximum clearance permitted has been within the limit.
  • Check the hinges carefully. At least three adequately fastened hinges should support the door. Check for any missing screws that might jeopardize the hinge’s integrity.
  • Putting the right signs on the fire door for non-domestic buildings or communal spaces in apartments is mandatory. In an emergency, these signs give critical information, directing residents.

These post-installation inspections verify that your fire door performs correctly and provides the protection intended.

Fire Door Functionality Maintenance

Installing fire doors is not enough; regular maintenance is also required to guarantee that they stay fully effective when needed. Fire doors must be inspected and maintained regularly, with a recommended frequency of once every six months. More regular inspections are recommended for doors that get a lot of activity and are more prone to wear and tear.

Regular inspection is required for the efficiency of fire doors, and Specialists should perform them. FDIS inspectors have a fire door diploma and have undertaken independent assessments to confirm their competence and expertise. Contacting an FDIS inspector guarantees that your fire doors are thoroughly inspected.

British Parameters

Fire doors’ integrity is maintained by conforming to British standards that set the bar for safety and dependability. Let us look at some of these critical standards:

BS 8214

This standard controls fire door specification, installation, and maintenance. It underlines that a fire door should provide fire resistance comparable to the permanent features of a building. Put another way, the fire door is the last line of defense and must be durable.

BS 5839-1:2013

BS 5839-1:2013 specifies how to install devices such as Door Hold Open Devices on a fire door. It is the standard by which such gadgets are evaluated. Proper installation is essential for ensuring that fire doors function.

BS 9999:2008

This standard is the practice code for fire safety in building design, management, and usage. It is critical in evaluating the fire safety strategy of existing buildings, new buildings, and additions or renovations to existing structures. Compliance with BS 9999:2008 guarantees fire safety, giving all residents peace of mind.

Your biggest ally in Fire door safety is knowledge and adherence to these standards.

With Ignis Door UK, you’re in Safe hands.

Fire door Specialists like Ignis Door are committed to protecting your safety and peace of mind. Our doors have solid cores with no foam or honeycomb filler, guaranteeing the highest quality and dependability standards.

Our services Include

  • Domestic internal doors
  • Fire doors FD30 and FD60 for the front entry

Put your faith in Ignis while you assess your fire safety requirements. We are more than a company; we are a committed partner on your road to increased safety.